Golden Electronics

Sequential Timer Card

Leading Manufacturers, Exporters and Wholesaler of DC Type Sequential Timer, Feedback & Auto Manual Sequential Timer, Offline Bag Filter System Sequential Timer and Standard Sequential Timer from Rourkela.

DC Type Sequential Timer

Get Best Price
Business Type Manufacturer, Supplier
Input supply Input supply 220v to 250v A/C, 50Hz
Channel(Output) 10 Channel (24V DC Output )
Temperature Operating Temperature Range 0 C to 50C,
Accuracy Repetitive Accuracy On Time sequence +/- 5 %
Dimensions Open type , 215mm length, 147mm wide ,and 48mm height.
Download View

Preferred Buyer From

Location India ( Bihar, Chhattisgarh, Jharkhand, Odisha, West Bengal)

SEQUENTIAL TIMER CARD designed by v-solutions is to operate the solenoid pilot valves used on dust collector equipment. LED provide visual indication of energized pilot valve in sequence, and also “power on “ indication. The number of sequence step is adjustable from 2 through 10.

 

Controls are provided to adjust the length of time between valves being energized ( pulse frequency ) and the length of time that the valve is energized ( pulse duration ). Silicon semiconductor components control all timing and logic functions.

 

Two independent methods of starting and stopping the timer are provided.

 

The first method will automatically stop the sequence and reset the controller to the first valve position whenever A/C power is removed and then reconnected. The second method is by a remote contact connected to the terminals provided.


Read More...


Yes! I am interested


Feedback & Auto Manual Sequential Timer

Get Best Price
Business Type Manufacturer, Supplier
Input supply Input supply 220v to 250v A/C, 50Hz
Channel(Output) 24 Channel (230v A/C Output )
Protection Main’s Incoming Fuse 3 Amps. Quick Blow Ceramic
Temperature Operating Temperature Range 0 C to 50C,
Accuracy Repetitive Accuracy On Time sequence +/- 5 %
Download View

Preferred Buyer From

Location India ( Bihar, Chhattisgarh, Jharkhand, Odisha, West Bengal)

SEQUENTIAL TIMER CARD designed by v-solutions is to operate the solenoid pilot valves used on dust collector equipment. LED provide visual indication of energized pilot valve in sequence, and also “power on “ indication. The number of sequence step is adjustable from 2 through 24.

 

Controls are provided to adjust the length of time between valves being energized ( pulse frequency ) and the length of time that the valve is energized ( pulse duration ). Silicon semiconductor components control all timing and logic functions.

 

Two independent methods of starting and stopping the timer are provided.

 

The first method will automatically stop the sequence and reset the controller to the first valve position whenever A/C power is removed and then reconnected. The second method is by a remote contact connected to the terminals provided.


Read More...


Yes! I am interested


Offline Bag Filter System Sequential Timer

Get Best Price
Business Type Manufacturer, Supplier
Voltage 220V
Rated Power 1-3kw
Automatic Grade Automatic
Driven Type Electric
Warrenty 2 Years
Feature Heat Resistance

Preferred Buyer From

Location India ( Bihar, Chhattisgarh, Jharkhand, Odisha, West Bengal)

Yes! I am interested


Standard Sequential Timer

Get Best Price
Business Type Manufacturer, Exporter, Supplier
Input supply Input supply 220v to 250v A/C, 50Hz
Channel(Output) 10 Channel (230v A/C Output )
Protection Main’s Incoming Fuse 3 Amps. Quick Blow Ceramic
Temperature Operating Temperature Range 0 C to 50C,
Accuracy Repetitive Accuracy On Time sequence +/- 5 %
Download View

Preferred Buyer From

Location India ( Bihar, Chhattisgarh, Jharkhand, Odisha, West Bengal)

SEQUENTIAL TIMER CARD designed by v-solutions is to operate the solenoid pilot valves used on dust collector equipment. LED provide visual indication of energized pilot valve in sequence, and also “power on “ indication. The number of sequence step is adjustable from 2 through 10.

 

Controls are provided to adjust the length of time between valves being energized ( pulse frequency ) and the length of time that the valve is energized ( pulse duration ). Silicon semiconductor components control all timing and logic functions.

 

Two independent methods of starting and stopping the timer are provided.

 

The first method will automatically stop the sequence and reset the controller to the first valve position whenever A/C power is removed and then reconnected. The second method is by a remote contact connected to the terminals provided.


Read More...


Yes! I am interested



Looking for Product Name ?

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.